| Model | CLO-2-T1(T2)
| CLO-3-T1(T2) |
Circulation
| Forced hot-air circulation with 4" exhaust outlet
|
Power Source
| AC 220V 3 Ø 60/50 Hz
|
Consumption Power
| 6(T1).9(T2) KVA
| 7.5(T1).10(T2) KVA
|
Performance
| Temperature Range
| T1 : 60 ~ 250°C ; T2 : 60 ~ 350°C
|
Temperature Stability
| ± 0.5 °C
|
Temperature Uniformity
| ± 1 °C at 100 °C ± 4 °C at 300 °C ± 2 °C at 200 °C ± 5 °C at 350 °C ± 3 °C at 250 °C
|
Warm - Up Time
| ambient temp. to 250 °C 35min ambient temp. to 350 °C 60min
|
Material
| Interior Material
| SUS 304# mirror finish stainless steel
|
Exterior Material
| SS 41# steel with baked paint
|
Heater
| SUS pipe sheath heater
|
| Insulation | 48K mineral Wool
|
| Safety Device | Leakage Circuit Break | Protection for leakage; short circuit and over current. (sensitivity 30mA) |
Fuse
| Rapid sensing with display; for heater and system protection.
|
Blowing Motor Protection
| Over - current protection (settable type)
|
over - current protection
| H. alarm protection and liquid expansion type auxiliary protection.
|
Trouble display
| Separately display for every trouble
|
Dimension
| Inside Dimensions (cm)
| 65 x 50 x 60 | 65 x 50 x 90 |
| | Outside Dimensions (cm)
| 85 x 103 x 152
| 85 x 103 x 182 |
Interior Capacity
| 180L
| 270L |