| Models |
NXO-2-T1
(T2) |
NXO-3-T1(T2) |
| Circulation |
forced hot-air circulation
with 4" exhaust outlet |
| Power Source |
AC 220V 3 Ø 60/50 Hz |
| Consumption Power |
6(T1).9(T2) KVA |
7.5(T1).10(T2) KVA |
| Performance |
Temperature Range |
T1 : 60 ~
250°C ; T2 : 60 ~ 350°C |
| Temperature Stability |
± 0.5 °C |
| Temperature Uniformity |
± 1 °C at 100 °C
±
4 °C at 300 °C
± 2 °C at 200 °C ±
5 °C at 350 °C
± 3 °C at 250 °C |
| Warm - Up Time |
ambient temp. to 250 °C 35min
ambient temp. to 350 °C 40min |
| Material |
Interior Material |
SUS 304# mirror finish stainless
steel |
| Exterior Material |
SS 41# steel with baked paint |
| Heater |
Ni - Cr alloy |
| Insulation |
48K mineral Wool |
| Inert Gas Lead-in- Device |
Lead-In Gas |
N2, CO2 (normal gaseous) |
| Gas Pressure |
input end Max. 10kg/cm²G; output end with
pressure adjusting device |
| Flow Volume |
max. 25/min. (at max flow volume) |
| Chamber Pressure |
3m/m Hg (at max. flow volume) |
| Duct |
brass; heat resistance up to 180°C |
| Pressure Gauge |
floating type |
| Release Valve |
action at pressure 0.5kg/cm² |
| Oxygen Containing Vlolume |
below 22PPM when finish inflation |
| Safety Devices |
Leakage Circuit Breaker |
Protection for leakage; short
circuit and over current. (sensitivity 30mA) |
| Fuse |
rapid sensing with display; for heater and system
protection. |
| Blowing Motor Protection |
over - current protection (settable
type) |
| Over-Temp Prevention |
H. alarm protection and liquid expansion type
auxiliary protection. |
| Trouble Display |
separately display for every
trouble |
| Dimension |
Inside Dimensions (cm) |
60 x 60 x 60 |
60 x 50 x 90 |
| Outside Dimensions (cm) |
92 x 80 x 133(T1)/145(T2) |
92 x 70 x 162(T1)/174(T2) |
| Interior Capacity |
216L |
270L |